SOFT START PLUS 1
Soft start starting electronic control panel 1 motor for the dry running control, clean water and sewage with display
-
Multi application control panel
-
Motor’s data auto learning
-
Well adaptive filling system
-
Adjustable acceleration and deceleration ramp
-
Events and alarms data logger
-
Protection for motherboard
-
Remote control SALUPO CONNECT
Applications
Optional
GENERAL SPECIFICATIONS
- Operating voltage 400Vac ±10% 50/60Hz
- General disconnecting switch with door lock
- Button for automatic operation
- Button for manual operation (stable/unstable)
- Siren shut-off button
- Auxiliary circuit protection fuse
- Motor protection fuse
- Soft start with by-pass contacts
- Forced ventilation with filters (from 25Hp)
- Thermostat for fan
- Connection terminal board
- External metal box
- Protection degree IP55
- Operating temperature -5/+40°C
ADVANTAGES
- Multilingual Display LCD to visualize:
- Operating voltage
- Current
- Cosφ
- Hour counter
- Level status
- System pressure with pressure transducer
- Tank level in meters with piezoresistive probe
- All information concerning the operation of the motor
- Motor’s data auto learning:
- Cosφ
- Minimum and maximum current
- Well adaptive filling system
- Adjustable maximum number of startings per hour
- Adjustable motor starting test (24-48-72-96h)
- Dry running with level control, cosφ and minimum current
- Adjustable probe sensitivity
- Emptying (1 input)/Filling (2 inputs) function
- Loss of pressure control
- Adjustable mains supply returning
- Siren shut-off
- Adjustable acceleration and deceleration ramp from trimmer
- Adjustable starting voltage from trimmer
- Operation with pressure switches, float switches, probes, pressure transducer and piezoresistive probe 4-20mA
INPUTS/OUTPUTS
- N°4 very low voltage inputs
- Input 4-20mA
- Very low voltage input for motor klixon
- N°2 alarm outputs 12Vdc max 200mA for siren and flashing Led lamp
- Alarm output max 5A NC-COM-NO (pure contact)
PROTECTIONS
- Maximum and minimum current protection with alarm
- Lack and sequence of phases protection with automatic resent and alarm
- Minimum and maximum voltage protection with automatic reset and alarm
- Motor klixon protection with automatic reset and alarm
THREE-PHASE 400Vac ± 10% 50/60Hz |
|||||||||
CODE | TYPE | POWER | OPERATING | DIMENSIONS mm | WEIGHT | BOX | |||
---|---|---|---|---|---|---|---|---|---|
kW | HP | CURRENT (A) | A-H | L-W | P-D | Kg | |||
SQ687.00/SS | SOFT START PLUS 1 400 5,5 | 2,2÷4 | 3÷5,5 | 5÷12,5 | 500 | 400 | 230 | 16 | 50 |
SQ687.01/SS | SOFT START PLUS 1 400 12,5 | 5,5÷9,2 | 7,5÷12,5 | 10÷25 | 500 | 400 | 230 | 16 | 50 |
SQ687.02/SS | SOFT START PLUS 1 400 17,5 | 11÷13 | 15÷17,5 | 17÷32 | 500 | 400 | 230 | 16 | 50 |
SQ687.03/SS | SOFT START PLUS 1 400 20 | 15 | 20 | 23÷38 | 500 | 400 | 230 | 16 | 50 |
SQ687.04/SS | SOFT START PLUS 1 400 25 | 18,5 | 25 | 22,5÷45 | 600 | 400 | 280 | 22 | 61 |
SQ687.05/SS | SOFT START PLUS 1 400 35 | 22÷26 | 30÷35 | 25,5÷63 | 600 | 400 | 280 | 22 | 61 |
SQ687.06/SS | SOFT START PLUS 1 400 40 | 30 | 40 | 34,5÷72 | 600 | 400 | 280 | 22 | 61 |
SQ687.07/SS | SOFT START PLUS 1 400 50 | 37 | 50 | 46÷106 | 700 | 500 | 290 | 29 | 71 |
SQ687.08/SS | SOFT START PLUS 1 400 60 | 45 | 60 | 46÷106 | 700 | 500 | 290 | 29 | 71 |
SQ687.09/SS | SOFT START PLUS 1 400 70 | 51,5 | 70 | 46÷106 | 700 | 500 | 290 | 29 | 71 |
SQ687.10/SS | SOFT START PLUS 1 400 80 | 60 | 80 | 59÷134 | 800 | 600 | 340 | 45 | 81 |
SQ687.11/SS | SOFT START PLUS 1 400 90 | 66 | 90 | 59÷134 | 800 | 600 | 340 | 48 | 81 |
SQ687.12/SS | SOFT START PLUS 1 400 100 | 75 | 100 | 87÷162 | 800 | 600 | 340 | 51 | 81 |
N.B.: When ordering, check the power and the rated current of the motor
OPTIONALS |
|||||||||
CODE | TYPE | ||||||||
---|---|---|---|---|---|---|---|---|---|
OP100.29/B | On board GPRS expansion | ||||||||
OP100.39/B | On board Ethernet expansion | ||||||||
OP100.49/B | On board MODBUS RS-485 expansion | ||||||||
OP100.59/B | On board Ethernet – WiFi – expansion | ||||||||
OP100.99/B | On board expansion to detect water in the oil chamber up to 3 motors | ||||||||
OP100.01 | 3 level probes kit | ||||||||
OP100.17/024 | Wired 24Vac relay complete with socket | ||||||||
OP100.05/1 | Wired three-phase surge arrester type 2 | ||||||||
SS100.00 | Visual and acoustic alarm indicator (BASIC ALARM VA012) | ||||||||
AC300.11.10-004.20 | Pressure transducer 0-10bar 4-20mA with 4m cable | ||||||||
AC300.11.16-004.20 | Pressure transducer 0-16bar 4-20mA with 4m cable | ||||||||
AC300.11.25-004.20 | Pressure transducer 0-25bar 4-20mA with 4m cable | ||||||||
AC300.20.01-005.00 | Piezoresistive probe 4-20mA with 5m cable | ||||||||
AC300.20.01-010.00 | Piezoresistive probe 4-20mA with 10m cable | ||||||||
AC300.20.02-010.20 | Piezoresistive probe 4-20mA with 10m cable for sewage |
For more optionals click here
SPARE PARTS |
|||||||||
CODE | TYPE | ||||||||
---|---|---|---|---|---|---|---|---|---|
AC100.22/1/50 | Display electronic board with flat cable 20pin 50cm | ||||||||
AC100.22/1/80 | Display electronic board with flat cable 20pin 80cm | ||||||||
AC100.22/1/100 | Display electronic board with flat cable 20pin 100cm | ||||||||
SD687.20/1 | Three-phase SOFT START PLUS electronic board 20A | ||||||||
SD687.30-40/1 | Three-phase SOFT START PLUS electronic board 30-40A | ||||||||
SD687.60/1 | Three-phase SOFT START PLUS electronic board 60A | ||||||||
SD687.100/1 | Three-phase SOFT START PLUS electronic board 100A | ||||||||
SD687.200/1 | Three-phase SOFT START PLUS electronic board 200A |