SOFT START 3

SOFT START 3

Soft start starting electromechanical control panel 3 motors with voltmeter and ammeters

  • Easy to program
  • Adjustable acceleration and deceleration ramp

GENERAL SPECIFICATIONS

  • Operating voltage 400Vac ±10% 50/60Hz
  • General disconnecting switch with door lock
  • N°3 selector switches for automatic -0- manual operation
  • N°3 start-stop buttons for manual operation
  • N°3 running Led lights
  • N°3 overload Led lights
  • Analog voltmeter 72×72
  • Voltmeter selector switch
  • N°3 analog ammeters 72×72
  • Auxiliary circuit protection fuse
  • Transformer for auxiliary circuit
  • Protection fuse for each  motor
  • N°3 soft start with by-pass contacts
  • Forced ventilation complete with filters (from 25Hp)
  • Thermostat for fan
  • Connection terminal board
  • External metal box
  • Protection degree IP55
  • Operating temperature -5/+40°C

ADVANTAGES

  • Adjustable acceleration and deceleration ramp by trimmer
  • Adjustable starting voltage by trimmer

INPUTS/OUTPUTS

  • N°2 very low voltage inputs for pressure switch or float switches (motor 1 minimum/maximum level)
  • N°2 very low voltage inputs for pressure switch or float switches (motor 2 minimum/maximum level)
  • N°2 very low voltage inputs for pressure switch or float switches (motor 3 minimum/maximum level)

PROTECTIONS

  • Maximum current protection for each motor with phases unbalance and alarm
  • Protection against lack of phase and missing load

THREE-PHASE 400Vac ±10% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SQ722.00 SOFT START 3 400 5,5 2,2÷4 3÷5,5 3x(5÷12,5) 800 600 290 35 80
SQ722.01 SOFT START 3 400 12,5 5,5÷9,2 7,5÷12,5 3x(10÷25) 800 600 290 35 80
SQ722.02 SOFT START 3 400 17,5 11÷13 15÷17,5 3x(17÷32) 800 600 290 35 80
SQ722.03 SOFT START 3 400 20 15 20 3x(23÷38) 800 600 290 35 80
SQ722.04 SOFT START 3 400 25 18,5 25 3x(22,5÷45) 1000 800 370 60 103
SQ722.05 SOFT START 3 400 35 22÷26 30÷35 3x(25,5÷63) 1000 800 370 62 103
SQ722.06 SOFT START 3 400 40 30 40 3x(34,5÷72) 1000 800 370 64 103
SQ722.07 SOFT START 3 400 50 37 50 3x(42,5÷58) 1200 800 370 73 122
SQ722.07/2 SOFT START 3 400 50 37 50 3x(46÷106) 1200 800 370 74 122
SQ722.08 SOFT START 3 400 60 45 60 3x(46÷106) 1200 800 370 75 122

 

OPTIONALS

CODE TYPE
OP100.04/4 Wired lack, sequence and asymmetry of phases relay
OP100.04/5 Wired lack, sequence and asymmetry of phases relay, minimum and maximum voltage
OP100.05/1 Wired three-phase surge arrester type 2
OP100.15/024 Wired hour counter 24Vac 48×4
OP100.15/110 Wired hour counter 110Vac 48×48
OP100.16/1 Wired analog daily timer 72×72 without reserve
OP100.16/2 Wired analog daily timer 72×72 with reserve
OP100.18 Wired starting delay timer (supply mains waiting)
OP100.19/4 Wired module GSM 4 inputs/4 outputs
OP100.09/2 Wired lithium battery 3,7Vdc 600mAh
OP333.230 Wired 230Vac MULTI 3 control relay for pressure booster and sewage
OP210.01 Wired very low voltage input for motor klixon
OP200.01  Alarm output 24Vac and pure contact
OP100.13/1 Wired siren shut-off button
OP100.13/1/24 Wired siren 24Vac/dc
OP100.13/2/24L Wired flashing Led lamp 24Vac
SS100.01 Visual and acoustic alarm indicator (BASIC ALARM VA024)
For more optionals click here