EVO 2

EVO 2

Direct starting electromechanical control panel 2 motors

 

  • Protection fuse for each motor

GENERAL SPECIFICATIONS

  • Operating voltage 230Vac ±10% 50/60Hz (SA651.xx)
  • Operating voltage 400Vac ±10% 50/60Hz (SA661.xx)
  • General disconnecting switch with door lock
  • N°2 selector switches for automatic -0- manual operation (stable)
  • Mains supply Led light
  • N°2 running Led lights
  • N°2 overload Led lights
  • Auxiliary circuit protection fuse
  • Transformer for auxiliary circuit
  • Protection fuse for each motor
  • N°2 contactors
  • N°2 thermal relays (internal reset)
  • Connection terminal board
  • External thermoplastic box
  • Cable glands
  • Protection degree IP65
  • Operating temperature -5/+40°C

PROTECTIONS

  • Maximum current protection for each motor with alarm

INPUTS/OUTPUTS

  • N°2 very  low voltage inputs for pressure switch or float switches (motor 1 minimum/maximum level)
  • N°2 very  low voltage inputs for pressure switch or float switches (motor 2 minimum/maximum level)

SINGLE-PHASE 230Vac ±10% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SA651.00L EVO 2 230 0,5 0,37 0,5 2x(2,5÷4) 380 300 150 6,4 05
SA651.01L EVO 2 230 0,75 0,55 0,75 2x(4÷6,5) 380 300 150 6,4 05
SA651.02L EVO 2 230 1 0,75 1 2x(6,3÷10) 380 300 150 6,4 05
SA651.03L EVO 2 230 1,5 1,1 1,5 2x(6,3÷10) 380 300 150 6,4 05
SA651.04L EVO 2 230 2 1,5 2 2x(9÷14) 380 300 150 6,4 05
SA651.05L EVO 2 230 3 2,2 3 2x(13÷18) 380 300 150 6,4 05

 

THREE-PHASE 400Vac ±10% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SA661.00L EVO 2 400 0,5 0,37 0,5 2x(1,1÷1,6) 380 300 150 6,4 05
SA661.01/02L EVO 2 400 1  0,55÷0,75 0,75÷1 2x(1,6÷2,5) 380 300 150 6,4 05
SA661.03L EVO 2 400 1,5 1 1,5 2x(2,5÷4) 380 300 150 6,4 05
SA661.04L EVO 2 400 2 1,5 2 2x(4÷6,5) 380 300 150 6,4 05
SA661.06/07L EVO 2 400 4  2,2÷3  3÷4 2x(6,3÷10) 380 300 150 6,4 05
SA661.09L EVO 2 400 5,5 4 5,5 2x(9÷14) 380 300 150 6,4 05
SA661.10L EVO 2 400 7,5 5,5 7,5 2x(13÷18) 380 300 150 6,4 05
SA661.11L EVO 2 400 10 7,5 10 2x(17÷23) 460 380 150 7,1 07
SA661.12L EVO 2 400 12,5 9,2 12,5 2x(20÷25) 460 380 150 7,1 07
SA661.13/14L EVO 2 400 17,5  11÷13  15÷17,5 2x(24÷32) 460 380 150 7,1 07
SA661.15L EVO 2 400 20 15 20 2x(32÷38) 460 380 150 7,3 07

 

OPTIONALS

CODE TYPE
OP100.02/0 Automatic -0- manual selector switch (from stable to unstable)
OP100.02/1 Wired start-stop button
OP100.04/4 Wired lack, sequence and asymmetry of phases relay
OP100.04/5 Wired lack, sequence and asymmetry of phases relay, minimum and maximum voltage
OP100.05 Wired single-phase surge arrester type 2
OP100.05/1 Wired three-phase surge arrester type 2
OP100.15/024 Wired hour counter 24Vac 48×48
OP100.16/1 Wired analog daily timer 72×72 without reserve
OP100.16/2 Wired analog daily timer 72×72 with reserve
OP100.19/4 Wired module GSM 4 inputs/4 outputs
OP100.09/2 Wired lithium battery 3,7Vdc 600mAh
OP210.01 Wired very low voltage input for motor klixon
OP200.01 Alarm output 24Vac and pure contact
OP100.13/1 Wired siren shut-off button
OP100.13/1/24 Wired siren 24Vac/dc
OP100.13/2/24L Wired flashing Led lamp 24Vac
SS100.01 Visual and acoustic alarm indicator (BASIC ALARM VA024)
For more optionals click here