AUTOTRANSFORMER 1

AUTOTRANSFORMER 1

Autotransformer starting electromechanical control panel 1 motor with voltmeter and ammeter

GENERAL SPECIFICATIONS

  • Operating voltage 400Vac ±10% 50/60Hz
  • General disconnecting switch with door lock
  • Selector switch for automatic -0- manual operation
  • Start-stop button for manual operation
  • Adjustable autotransformer timer
  • Running Led light
  • Overload Led light
  • Analog voltmeter 72×72
  • Voltmeter selector switch
  • Analog ammeter 72×72
  • Auxiliary circuit protection fuse
  • Transformer for auxiliary circuit
  • Motor protection fuse
  • N°3 contactors
  • Three-phase autotransformer with thermostat
  • Thermal relay (internal reset)
  • Connection terminal board
  • External metal box
  • Protection degree IP55
  • Operating temperature -5/+40°C

PROTECTIONS

  • Maximum current protection with alarm

INPUTS/OUTPUTS

  • N°2 very  low voltage inputs for pressure switch or float switches (minimum/maximum level)

THREE-PHASE 400Vac ±10% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SQ705.00 AUTOTRANSFORMER 1 400 10 7,5 10 14÷20 700 500 290 29 71
SQ705.01 AUTOTRANSFORMER 1 400 12,5 9,2 12,5 20÷25 700 500 290 29 71
SQ705.02 AUTOTRANSFORMER 1 400 15 11 15 23÷28 700 500 290 31 71
SQ705.03 AUTOTRANSFORMER 1 400 17,5 13 17,5 27÷32 700 500 290 32 71
SQ705.04 AUTOTRANSFORMER 1 400 20 15 20 30÷36 700 500 290 33 71
SQ705.05 AUTOTRANSFORMER 1 400 25 18,5 25 40÷50 700 500 290 40 71
SQ705.06 AUTOTRANSFORMER 1 400 30 22 30 47÷57 800 600 290 42 80
SQ705.07 AUTOTRANSFORMER 1 400 35 26 35 54÷65 800 600 290 42 80
SQ705.08 AUTOTRANSFORMER 1 400 40 30 40 62÷73 800 600 290 46 80
SQ705.09 AUTOTRANSFORMER 1 400 50 37 50 70÷90 800 600 290 58 80
SQ705.10 AUTOTRANSFORMER 1 400 60 45 60 50÷200 1000 800 370 85 103
SQ705.11 AUTOTRANSFORMER 1 400 70 51,5 70 50÷200 1000 800 370 90 103
SQ705.12 AUTOTRANSFORMER 1 400 75 55 75 50÷200 1000 800 370 90 103
SQ705.13 AUTOTRANSFORMER 1 400 80 60 80 50÷200 1000 800 370 93 103
SQ705.14 AUTOTRANSFORMER 1 400 90 66 90 50÷200 1000 800 370 103 103
SQ705.15 AUTOTRANSFORMER 1 400 100 75 100 50÷200 1000 800 370 103 103
SQ705.16 AUTOTRANSFORMER 1 400 150 92 125 55÷250 1200 800 370 120 122
SQ705.17 AUTOTRANSFORMER 1 400 125 110 150 160÷630 1800 800 470 195 185
SQ705.18 AUTOTRANSFORMER 1 400 180 132 180 160÷630 1800 800 470 205 185
SQ705.19 AUTOTRANSFORMER 1 400 200 150 200 160÷630 1800 800 470 210 185

 

OPTIONALS

CODE TYPE
OP100.04/4 Wired lack, sequence and asymmetry of phases relay
OP100.04/5 Wired lack, sequence and asymmetry of phases relay, minimum and maximum voltage
OP100.05/1 Wired three-phase surge arrester type 2
OP100.15/024 Wired hour counter 24Vac 48×4
OP100.15/110 Wired hour counter 110Vac 48×48
OP100.16/1 Wired analog daily timer 72×72 witout reserve
OP100.16/2 Wired analog daily timer 72×72 with reserve
OP100.18 Wired starting delay timer (supply mains waiting)
OP100.19/4 Wired module GSM 4 inputs/4 outputs
OP100.09/2 Wired lithium battery 3,7Vdc 600mAh
OP331.230 Wired 230Vac LEVEL control relay
OP100.01  3 level probes kit
OP100.17/024 Wired 24Vac complete with socket
OP210.01 Wired very low voltage input for motor klixon
OP200.01 Alarm output 24Vac and pure contact
OP100.13/1 Wired siren shut-off button
OP100.13/1/24 Wired siren 24Vac/dc
OP100.13/2/24L Wired flashing Led lamp 24Vac
SS100.01 Visual and acoustic alarm indicator (BASIC ALARM VA024)