MULTI 1
Direct starting electronic control panel 1 motor for clean water and sewage
-
Multi application control panel
-
Single-phase version with power relay for inductive loads (up to 31A)
-
Protection for motherboard
Applications
Optional
GENERAL SPECIFICATIONS
- Operating voltage 230Vac +15/-20% 50/60Hz (SA664.xx)
- Operating voltage 400Vac +15/-20% 50/60Hz (SA667.xx)
- General disconnecting switch with door lock
- Button for automatic -0- manual operation
- Siren shut-off button
- Maximum current trimmer
- Timed probe trimmer 1÷240min
- Probe sensitivity trimmer 1÷100kohm
- “POWER” Led light (supply mains)
- Running Led light
- Motor overload Led light
- Motor klixon intervention Led light
- Motor status Led light
- “FUNCTION” Led light (inputs status)
- “ALARM” Led light (level status)
- Auxiliary circuit protection fuse
- Motor protection fuse
- Contactor (SA667.xx)
- External thermoplastic box
- Cable glands
- Protection degree IP65
- Operating temperature -5/+50°C
- Relative humidity 60% at 50°C (not condensed)
ADVANTAGES
- Configuration via Dip switch
- Dry running with 3 or 2 timed probes level control
- Adjustable probes sensitivity
- Emptying (1 input)/Filling (2 inputs) function
- Siren shut-off
- Operation with pressure switches, float switches and probes
INPUTS/OUTPUTS
- N°4 very low voltage inputs
- Very low voltage input for motor klixon
- N°2 alarm outputs 12Vdc max 200mA for siren and flashing Led lamp
- Alarm output max 5A NC-COM-NO (pure contact)
PROTECTIONS
- Maximum current protection with alarm
- Lack and sequence of phases protection with automatic reset and alarm
- Deactivable minimum and maximum voltage protection with automatic reset and alarm
- Motor klixon protection with automatic reset and alarm
SINGLE-PHASE 230Vac +15/-20% 50/60Hz |
|||||||||
CODE | TYPE | POWER | OPERATING | DIMENSIONS mm | WEIGHT | BOX | |||
---|---|---|---|---|---|---|---|---|---|
kW | HP | CURRENT (A) | A-H | L-W | P-D | Kg | |||
SA664.00 | MULTI 1 230 | 0,37÷2,2 | 0,5÷3 | 2÷18 | 285 | 245 | 140 | 2,2 | 03 |
THREE-PHASE 400Vac +15/-20% 50/60Hz |
|||||||||
CODE | TYPE | POWER | OPERATING | DIMENSIONS mm | WEIGHT | BOX | |||
---|---|---|---|---|---|---|---|---|---|
kW | HP | CURRENT (A) | A-H | L-W | P-D | Kg | |||
SA667.02L | MULTI 1 400 10 | 0,37÷7,5 | 0,5÷10 | 0,5÷16 | 285 | 245 | 140 | 2,7 | 03 |
SA667.03L | MULTI 1 400 15 | 2,2÷11 | 3÷15 | 4÷25 | 345 | 285 | 165 | 3,3 | 04 |
SA667.04L | MULTI 1 400 20 | 7,5÷15 | 10÷20 | 16÷32 | 345 | 285 | 165 | 3,4 | 04 |
OPTIONALS |
|
CODE | TYPE |
---|---|
OP100.01 | 3 level probes kit |
OP100.17/024 | Wired 24Vac relay complete with socket |
Op100.17/230 | Wired 230Vac relay complete with socket |
OP100.05 | Wired single-phase surge arrester type 2 |
OP100.05/1 | Wired three-phase surge arrester type 2 |
OP100.13/1/12 | Wired siren 12Vdc |
OP100.13/2/12L | Wired flashing Led lamp 12Vdc |
SS100.00 | Visual and acoustic alarm indicator (BASIC ALARM VA012) |
OP00.10 | Couple of brackets for collar (reference BOX 03-04) |
Fore more optionals click here
SPARE PARTS |
|||||||||
CODE | TYPE | ||||||||
---|---|---|---|---|---|---|---|---|---|
AC100.24/30 | Led electronic board 1 pump with siren shut-off button and flat cable 20pin 30cm | ||||||||
SD664.20/1 | Single-phase MULTI 1 electronic board | ||||||||
SD667.20/1 | Three-phase MULTI 1 electronic board 20A | ||||||||
SD667.30-40/1 | Three-phase MULTI 1 electronic board 30-40A |