MULTI 1

MULTI 1

Direct starting electronic control panel 1 motor for clean water and sewage

  • Multi application control panel
  • Single-phase version with power relay for inductive loads (up to 31A)
  • Protection for motherboard

GENERAL SPECIFICATIONS

  • Operating voltage 230Vac +15/-20% 50/60Hz (SA664.xx)
  • Operating voltage 400Vac +15/-20% 50/60Hz (SA667.xx)
  • General disconnecting switch with door lock
  • Button for automatic -0- manual operation
  • Siren shut-off button
  • Maximum current trimmer
  • Timed probe trimmer 1÷240min
  • Probe sensitivity trimmer 1÷100kohm
  • “POWER” Led light (supply  mains)
  • Running Led light
  • Motor overload Led light
  • Motor klixon intervention Led light
  • Motor status Led light
  • “FUNCTION” Led light (inputs status)
  • “ALARM” Led light (level status)
  • Auxiliary circuit protection fuse
  • Motor protection fuse
  • Contactor (SA667.xx)
  • External thermoplastic box
  • Cable glands
  • Protection degree IP65
  • Operating temperature -5/+50°C
  • Relative humidity 60% at 50°C (not condensed)

ADVANTAGES

  • Configuration via Dip switch
  • Dry running with 3 or 2 timed probes level control
  • Adjustable probes sensitivity
  • Emptying (1 input)/Filling (2 inputs) function
  • Siren shut-off
  • Operation with pressure switches, float switches and probes

INPUTS/OUTPUTS

  • N°4 very low voltage inputs
  • Very low voltage input for motor klixon
  • N°2 alarm outputs 12Vdc max 200mA for siren and flashing Led lamp
  • Alarm output max 5A NC-COM-NO (pure contact)

PROTECTIONS

  • Maximum current protection with alarm
  • Lack and sequence of phases protection with automatic reset and alarm
  • Deactivable minimum and maximum voltage protection with automatic reset and alarm
  • Motor klixon protection with automatic reset and alarm

SINGLE-PHASE 230Vac +15/-20% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SA664.00 MULTI 1 230 0,37÷2,2 0,5÷3 2÷18 285 245 140 2,2 03

 

THREE-PHASE 400Vac +15/-20% 50/60Hz

CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW HP CURRENT (A) A-H L-W P-D Kg
SA667.02L MULTI 1 400 10 0,37÷7,5 0,5÷10 0,5÷16 285 245 140 2,7 03
SA667.03L MULTI 1 400 15 2,2÷11 3÷15 4÷25 345 285 165 3,3 04
SA667.04L MULTI 1 400 20 7,5÷15 10÷20 16÷32 345 285 165 3,4 04

 

OPTIONALS

CODE TYPE
OP100.01 3 level probes kit
OP100.17/024 Wired 24Vac relay complete with socket
Op100.17/230 Wired 230Vac relay complete with socket
OP100.05 Wired single-phase surge arrester type 2
OP100.05/1 Wired three-phase surge arrester type 2
OP100.13/1/12 Wired siren 12Vdc
OP100.13/2/12L Wired flashing Led lamp 12Vdc
SS100.00 Visual and acoustic alarm indicator (BASIC ALARM VA012)
OP00.10 Couple of brackets for collar (reference BOX 03-04)
Fore more optionals click here

 

SPARE PARTS

CODE TYPE
AC100.24/30 Led electronic board 1 pump with siren shut-off button and flat cable 20pin 30cm
SD664.20/1 Single-phase MULTI 1 electronic board
SD667.20/1 Three-phase MULTI 1 electronic board 20A
SD667.30-40/1 Three-phase MULTI 1 electronic board 30-40A